LG LRMVS3006DRefrigerator

Error Code E CH

High Side Cycle Leakage — Sealed System Problem

Moderate

Address soon - your appliance may not work properly

Also displayed as: CH E

How to Fix

  1. 1

    Use SVC App Step 1 to determine if this is a compressor or sealed system problem, or a normal (customer emotional) fault. If no SVC App, use a temperature gun to check evaporator temperature.

  2. 2

    Check PCB output voltage to rule out PCB failure. If PCB is bad, replace PCB.

  3. 3

    Measure time for pressure equalization between high side (drier) and low side (compressor process pipe) after power off. If equalization takes more than 15 minutes, system is restricted.

  4. 4

    If equalization pressure is above 40 psi, refrigerant is present — suspect bad compressor. Replace compressor.

  5. 5

    If equalization pressure is 40 psi or less, refrigerant has leaked. Proceed to leak testing.

  6. 6

    Check high pressure side parts (condenser, drier, compressor discharge pipe) for leaks using bubble solution or refrigerant leak detector.

  7. 7

    If no high side leak found, check low pressure side parts (evaporator, suction pipe).

  8. 8

    Repair any leak found, replace all leaking parts plus the drier.

  9. 9

    After repair, wait until freezer reaches 14F or below — error code will clear automatically.

  10. 10

    If temperature is normal and E CH persists, use forced deletion: press F key + R key 3 times with door open.

  11. 11

    Use UV drier on next visit to verify no further leaks via UV light and UV goggles.